Custom Adult CPR simulator with color touch screen control Manufacturers, Manufacturer

Cardiopulmonary resuscitation simulator is a first-aid training model developed based on the latest International Cardiopulmonary Resuscitation (CPR)&Emergency Cardiovascular Care (ECC) Guideline Standards of American Heart Association(AHA).

The adult color touch screen CPR simulator mainly has the following functions:

Simulate electrocardiogram; simulate carotid artery pulsation; data statistics, rectangular graph display, voice prompt, wireless connection( only for wireless version), pupil light reflex(only for pupil light reflex version only).

Product Description

Product Description

Three Operational Modes

Training Mode
Allows unrestricted compression and ventilation practice.
Assessment Mode
Evaluates operators according to the latest AHA guideline standards, with chest compression to artificial respiration ratio of 30:2, completing 5 cycles.
Scenario Mode
Allows self-adjustment of operational parameters (operation time, operation frequency, compression-to-ventilation ratio, cycle count, volume, scoring coefficients, etc.).

Primary Functions

  • Electronic Feedback: Equipped with electronic devices that provide rapid and accurate feedback on chest compression position, depth, frequency, and ventilation volume accuracy.
  • Voice Prompts: Volume is adjustable, with options to enable or disable voice. Provides detailed error reasons during compression (e.g., incorrect compression position, incorrect compression depth, incorrect compression frequency, incomplete chest recoil). Instructs "please open airway" when the airway is not open.
  • Dynamic Bar Display: Shows real-time compression depth and ventilation volume:
    • Yellow zone illuminated for insufficient compression/ventilation.
    • Yellow and green zones illuminated for correct compression/ventilation.
    • Yellow, green, and red zones illuminated for excessive compression/ventilation.
  • Indicator Light Display: Red lights indicate incorrect compression position. Airway indicator light shows green after airway is successfully opened.
  • LCD Counting & ECG Display: Provides detailed recordings of correct/incorrect compression and ventilation counts, and average frequency. Simulated electrocardiogram with bar chart records specific reasons for correct or incorrect operations.
  • Record & Replay: Allows operational procedures to be recorded and replayed for evaluation.

Simulated Vital Signs

Initial State
Simulator pupils dilated, no carotid pulse.
During Compression
Simulator carotid artery passive pulsation occurs, pulse frequency consistent with compression frequency.
After Successful Resuscitation
Simulator pupils automatically constrict, spontaneous carotid artery pulsation begins.

Printable Performance Reports

Supported on print-enabled models only. Report content includes:
Performance evaluation, operational mode, assessment environment, consciousness assessment, respiratory examination, pulse examination, emergency call, foreign body clearance, correct ventilation count, incorrect ventilation count and reasons, correct compression count, incorrect compression count and reasons, cycle count, compression-to-ventilation ratio, operational accuracy rate, set time, operation time, set frequency, frequency accuracy rate, implementation standards, and other details.
Pupillary Light Reflex
After successful resuscitation, illuminating one eye's pupil causes bilateral pupil constriction, rendering vital signs more realistic.
Wireless Connection
Features a built-in WiFi module eliminating the need for a data cable connection between model and controller. Equipped with two rechargeable power banks (one for model, one for controller) for convenient outdoor use and simple installation.
Notes:
  • All models can be configured in a half-body configuration.
  • Language and software configurations can be customized (please consult for details).
Frequently Asked Questions
What operational modes does the CPR simulator support?
The simulator supports three modes: Training Mode for unrestricted practice, Assessment Mode for evaluation based on AHA standards, and Scenario Mode for customized settings of operational parameters.
How does the simulator display real-time feedback during chest compression?
Feedback is provided via voice prompts indicating error details, a dynamic bar display showing compression depth and ventilation accuracy, and red/green indicator lights showing correct positions and airway statuses.
Can performance results be printed from this system?
Yes, print-enabled models support printing detailed performance evaluation reports. The reports cover assessment parameters, cycle count, frequency accuracy, operational accuracy rate, and other implementation details.
What simulated vital signs are built into the training model?
It features pupils that constrict and carotid pulses that begin spontaneously after successful resuscitation. In the initial state, pupils are dilated with no pulse, and passive carotid pulsation occurs during chest compressions.
Does the CPR training model require data cable connections?
No, it supports wireless connection via a built-in WiFi module between the model and the controller. It is equipped with two rechargeable power banks, ensuring seamless outdoor utility.
Can the language and design configuration be customized?
Yes, all models can be constructed as a half-body configuration, and both language and software functions can be customized to suit specific needs.

Related Products